Voltage regulators





       




 

Part Description Features Options Remarks Manual
LX10.1
AVR for PMG, SE, Aux. supply and DC supply
  • Underspeed protection
  • Self excitation
  • Phaseloss detection
  • Parallel operation
  • Soft start
Widely applicable
Stamford Nupart Series 4 KASR10
replacement AVR for series 4 and series 6
Newage MC,HC,UC, Nupart Series 3, Series 4
retrofit for either PMG or SE generator
using universal avr type LX10.1
Measuring transformer
Measuring-Sensing transformer
660-400-230 Volt 50/60 Hertz 50 VA
Leroy Somer CIN81 R130 R128 RT01 ARES LX10
Leroy Somer CIN81 R130 R128 RT01 ARES LX10
Various connection diagram with and without comp.
Leroy Somer CIN81
see also retrofit diagrams Leroy Somer
NEBB Brown Boveri SF7 3TX20 BBC
Replacement avr for NEBB SF7 avr systems
Air Curtain / Luchtgordijn
extended control for aircurtain / luchtgordijn
Besturings kast voor machine besturingen
Machine control
Design and manufacturing of machinecontrol
Regulated DC Power Supply ( High Current )
Voltages and Current on demand
limitting and other features possible
TES besturing ( BESAM Total Entrance System )
controller for BESAM automatic door system
http://www.besam.se/Local/BE-Dutch/Local%20Downloa
3FDIMMER / 3 PHASE AC controller
3 PHASE AC controller 16 Amp
Various currents available
Kantelschakelaar / Tiltswitch
Tiltswitch-Scheefstand beveiliging-Scheefhang
24 V& 48 V available
Markon Contrology AVR6E LS4000
Markon Contrology AVR6e LS4000
AEG TR5D
AEG TR5D avr
see retrofit diagrams for LX10.1
A.vanKaick DISB ( TO112 )
AvK TO18-TO19 exc. system (A.van Kaick)
AvK TO18-TO19 exc. system (A.van Kaick)
AEG LDW DKBH TR5D ( LX10.1 )
AEG LDW TR5D LX10.1 retrofit
best is EMRI Droopkit ( then omit resistor )
Kabel-zwerfkasten tester Cable distriboxtester
film / movie gebruik / use of tester
Volautomatische tester voor NEN3140 keuringen
Mitsubishi VRG BSN4 replacement
3TX20 for mitsubishi generator VRG BSN avr
LSA AREP PMG LSA R438 LSA R448 LSA R449
Retrofit LSA LX10.1
KASR10
Basic AVR
  • Underspeed protection
  • Self excitation
Marathon SE350 AVR - KASR10
replacement avr
  • Self excitation
low cost easy to apply universal replacement
ABB AMG AVC63-7 LX10 LX20
ABB AMG retrofit opt. series boost
Product Sheet Word Document
List of most used products and Selection guide
ECC BRF PM1 PM2 Wolverhampton
ECC BRF PM1 PM2 THR150 replacement avr
  • Parallel operation
with application diagram
Alconza NIR XR2002F
Retrofit for Basler XR2002F
  • Self excitation
Universal avr LX10.1
Basler XR2002 F
Retrofit for Basler XR2002F
used in Alconza NIR Generators
NEBB Brown Boveri SF7
see SF7 replacement product with all details
Due to several models, send genuine gen diagram
EFA DOLMEL TUR-A retrofit ASR150
TUR-A TUR/A Slipring generator DOLMEL retrofit
CATAVR2.3
CAT type SE, PMG as well 240,480 Volt replacement
  • Self excitation
  • Parallel operation
CatAVR2.1a replaces all types VR3
KASR20
Universal single phase avr suit. parallel
  • Parallel operation
  • Self excitation
separated supply and sensing ( option connector )
Spannungsregler
spannungsregler, synchron generator, erreger
statikwandler, hilfserreger, parallelbetrieb
DAE DEL Dansk Elektromotor Lager GA 4-5-6 RA1-..B
replacement diagram for RA1...B avr for DAE DEL
issue your application upon order choice for adv.
Uljanik 1FC retrofit
exchange compound to 3TX20
AvK Cosimat N8
AvK Cosimat N8 automatic voltage regulator
  • Parallel operation
can be replaced by LX10.1
AvK Cosimat N+
A van Kaick (AvK) Cummins AVR
  • Parallel operation
  • Power factor control
EVA
Replacement for R280/290, Ti7.5D, R260/274/261
  • Parallel operation
AvK, EME replacement
LX4V2
AVR with protections Can Bus programm. and readout
  • Underspeed protection
  • Self excitation
  • Phaseloss detection
  • Parallel operation
  • Current Limiting
Can Bus equipped
LX321
Multifunctional Newage MX321 replacement
  • Underspeed protection
  • Soft start
  • Self excitation
  • Phaseloss detection
  • Parallel operation
  • Current Limiting
  • Soft start
  • Power factor control
showed non encapsulated
SX440 / AS440
Stamford Newage SE avr
  • Parallel operation
AS440 replaces SX440
R438
Leroy Somer R438
  • Parallel operation
voor LSA
A.vanKaick TO18-TO19 replacement
AvK TO18-TO19 exc. system (A.van Kaick)
  • Self excitation
Uses LX10.1 universal avr
MX341
Newage avr
Rotating diode M5 Stud
Rotating diode M5 Stud
Rotating diode M6 Stud
Rotating diode M6 Stud
Forward and Reverse type
Rotating diode M8 stud with lead
Rotating diode M8 Stud with lead
Rotating diode M8 stud ( no lead )
Rotating diode M8 stud ( no lead )
Rotating diode module SKKD46, 82 type
Rotating diode module SKKD46, 82 type
AvanKaick
Rotating diode module DD89 type
Rotating diode module DD89 type
AvanKaick
Rotating diode module SKKD162 type
Rotating diode module SKKD162 type
Rectifier SKD50 model
Rectifier SKD50 model
suitable for rotating application
Rectifier SKD30 model
Rectifier SKD30 model
Rectifier SKD/SKB25 model
Rectifier SKD/SKB25 model
TRAFLX500 - 1000
Isolated stepdown transformer
Fully encapsulated with terminals
Anti condensation heating / space heater
230 Volt 50 Hertz standheater/anti condensation
250 Watt
MX321
MX321 ( Newage Stamford'
  • Parallel operation
see also EMRI LX321
Current Transformer 5 Amp (large hole )
Current Transformer 5A
available in 200,500,750,1000,1500 and 2000 Amp
replacement
replacement
Rotating rectifier
Complete Rotating frame with diodes
Innerdiam: 35 mm Outer diam: 115mm
Rotating rectifier
Complete Rotating frame with diodes
Innerdiam: 45 mm Outer diam: 115mm
Rotating rectifier
Complete Rotating frame with diodes
Innerdiam: 58 mm Outer diam: 140 mm
Rotating rectifier
Complete Rotating frame with diodes
Innerdiam: 70 mm Outer diam: 140 mm
Rotating rectifier
Complete Rotating frame with diodes (Piller)
Innerdiam: 85 mm Outer diam: 170 mm
Rotating rectifier
Complete Rotating frame with diodes (Piller)
Innerdiam: 120 mm Outer diam: 260 mm
Rotating rectifier
Newage HC4-5 rotating rectifier assembly
362-12800
Rotating diode M12 Stud
Rotating diode M12 Stud
Rotating rectifier
Newage HC7 rotating rectifier assembly
760-1008
Rotating diode M16 stud with lead
Rotating diode M16 stud with lead
Rotating diode M24 stud with lead
Rotating diode M24 stud with lead
Temperature alarm monitor winding-bearing
PT100 sensor 24 VDC - 24VAC-230VAC versions
two thresholds: pre-alarm and alarm contacs
Potmeter 25 Watt 10e
Caterpillar drooppotmeter
R280 R290 AVR
Complete with mounting skid
  • Parallel operation
for AvK and EME generators ( see EMRI LX4V2 )
T01 avr
T01 avr
AvK DIB Generators ( see retrofit diagrams )
TO112 AVR
TO112
AvK DISB / Fenya FNIC ( see retrofit diagrams )
Reliance - Alstom TR4
TR4 avr
ACEO Leroy Somer
RS128 replacement avr ( see retrofit diagrams )
Siemens TRUT 54340072
see retrofit diagrams
Newage SX460
See KASR10 and retrofit diagrams
AvK TO18-19 Avk DIDB
see retrofit diagrams
AvK TO3233 AvK DIDB
see retrofit diagrams
Thermax PTC - Thermistor relay
230 VAC / 24 VDC
test / autoreset
Voltage Match Unit TSV
Matches and enables matched voltages (Bus-Gen)
Unelec Alstohm AT250 AT315 AT400 generators
RS182 FRM FRN RS182 15066-1954-H21506
Garbe Lahmeijer, Lindenberg Aggregate
Unelec Alsthom 15074-1100 RBC
See retrofit diagrams
See EMRI RBC1100 replacement
RBC1100
Unelec Alsthom 15074-1100 replacement
  • Parallel operation
Heemaf SS (GUC/manual/Compound) HOLEC
Compound slipring generator ( EMRI ASR***)
  • Parallel operation
  • Power factor control
A.vanKaicK DIB T01 2 LX10.1 retrofit
AvK T01 to LX10.1
  • Parallel operation
Homopolaire motor
Uitleg homopolaire motor
http://www.walter-fendt.de/ph14nl/lorentzforce_nl.
LX500
LX500 is the Volt per Hertz version LX10.1
  • Underspeed protection
  • Self excitation
  • Phaseloss detection
  • Parallel operation
LX10.1 with extended functions
LASR11.1
Basic AVR for SE generators
  • Underspeed protection
  • Self excitation
  • Parallel operation
parallel operation with special droopkit
3TX20
3TX20
  • Self excitation
  • Phaseloss detection
  • Parallel operation
Universal AVR with wide supply range
CATAVR2.1a (Caterpillar VR3 VR6 replacement)
CAT type SE, PMG as well 240,480 Volt replacement
  • Underspeed protection
  • Self excitation
  • Parallel operation
CatAVR2.1a replaces all types VR3
ASR35
AVR for higher exciter currents (static exciter)
  • Underspeed protection
  • Self excitation
  • Phaseloss detection
  • Parallel operation
generally for slipring generators
NOZERO35
AVR for direct Phase-Phase supply
  • Underspeed protection
  • Self excitation
  • Phaseloss detection
  • Parallel operation
applicable when no neutral available
ASR100 ASR150 ASR250
Static Exciter (AVR) for slipring generators
  • Underspeed protection
  • Self excitation
  • Phaseloss detection
  • Parallel operation
self excitation provided
NOZERO100 NOZERO150 NOZERO250
Static Exciter (AVR) for slipring generators
  • Underspeed protection
  • Self excitation
  • Phaseloss detection
  • Parallel operation
self excitation provided
LX_VPH
Volt per Hertz en soft start ( current limit )
  • Underspeed protection
  • Soft start
  • Parallel operation
  • Current Limiting
  • Soft start
AFSNOEP
Thyripart / Indar / Huyndai / Wuxi anti par. thyr
  • Parallel operation
  • Power factor control
Is leverbaar in diverse capaciteiten
COSPHI 3.2
Power factor controller option for EMRI avr's
  • Voltage matching
LA2N
Battery charger
DIM100
Dimmer for inductive and resistive loads
IB40
Isolation guard for mobile gensets
showed model is version (Giet + Keyboard)
NKT-SS Piller400
Piller NKT compatible avr (400 Volt model)
  • Parallel operation
1:1 replacement for 400 Volt models NKT-SS
SX460 KASR10
1:1 SX460 replacement
  • Underspeed protection
  • Self excitation
fits and replaces SX460 1:1 more rugged
Droopkit ( for parallel operation with EMRI avrs )
Paralleling module for reactive power sharing
200,500,750,1000,1500,2000 and 3000 Amp available